Error Code

Brief Description

Description

Solution

ErrorCode_01 Grinder blocked Grinder blocked: there is the absence of pulses from the grinder. In this case the C.A. It hangs in the instant in which the user asks the machine to dispense a drink made of coffee (only coffee beans). Remove all of the beans from the grinder. Set grinder to coarsest setting. Vacuum clean the hopper and chute. Add dry beans and pull 2-3 shots. Adjust grind to preference one setting at a time, and brewing a shot between each adjustment.
ErrorCode_03 Brewing UNIT blocked work Brewing unit blocked work: Occurs when the brewing unit can not move from work to the home position. Remove the brew unit, and trip the microswitch with an index card or dollar bill. Power cycle the machine. If the brew unit moved to work and home position without much resistance, and no error codes appear, then the brew unit be damaged. If the error code persists, with the microswitch tripped, then the machine needs to be serviced for the brew unit drive motor.
 ErrorCode_04 Brewing UNIT blocked home Brewing unit blocked home: Occurs when the brewing unit can not move from home to the work position Remove the brew unit, and trip the microswitch with an index card or dollar bill. Power cycle the machine. If the brew unit moved to work and home position without much resistance, and no error codes appear, then the brew unit be damaged. If the error code persists, with the microswitch tripped, then the machine needs to be serviced for the brew unit drive motor.
 ErrorCode_05 Water circuit interrupted Water circuit interrupted: occurs when the flow meter is broken, disconnected or It does not occur passage of water. In these cases, since the C.A. can not correctly read the pulses of water, enters alarm condition “CHARGING CIRCUIT” in the moment in which the user asks to dispense a product: if the “charging circuit” fails C.A. blocked. The unit will need professional repairs.
 ErrorCode_06 DC valve short circuit DC Valve short circuit: occurs when one of the valves of the flute is shorted circuit. Such a problem may occur during dispensing of a product based on milk. The unit will need professional repairs.
 ErrorCode_10 Coffee temp. sensor short circuit Coffee temp. sensor short circuit: occurs when the temperature sensor coffee boiler is shorted. This error causes a blocking in C.A. to start-up. The unit will need professional repairs.
ErrorCode_11 Coffee temp. sensor open circuit Coffee temp. sensor open circuit: occurs when the temperature sensor coffee boiler is not detected. The problem is due to the absence of the signal of the sensor and does not allow to determine the C.A. the actual temperature of the boiler coffee. At start up, the C.A. blocked. The unit will need professional repairs.
 ErrorCode_12 Steam temp. sensor open circuit Steam temp. sensor open circuit: occurs when the temperature sensor steam boiler is not detected. The problem is due to the absence of the signal of the sensor and does not allow to determine the C.A. the actual temperature of the boiler steam. At start up, the C.A. blocked. The unit will need professional repairs.
ErrorCode_13 Steam temp. sensor short circuit Steam temp. sensor short circuit: occurs when the temperature sensor boiler steam is shorted. This error causes a blocking in C.A. to start-up. The unit will need professional repairs.
 ErrorCode_14 Boiler coffee timeout Boiler coffee timeout: occurs when no power coming to the boiler coffee, this does not reach the predetermined temperature within a time equal to 120 seconds. At start-up the AC, is continually on the screen HOLD FIRST TEMPERATURE, with the message “Warming up ...”, and after the expiry of the time Out to fault The unit will need professional repairs.
ErrorCode_15 Boiler steam timeout Boiler steam timeout: occurs when no power coming to the boiler steam, this does not reach the predetermined temperature within a time equal to 120 seconds. The unit will need professional repairs.
ErrorCode_16 Brewing unit short circuit Coffee boiler overheating: occurs when the temperature of the coffee boiler exceeds 150 ° C. The unit will need professional repairs.
ErrorCode_19 Zero crossing error Steam boiler overheating: occurs when the temperature of the steam boiler exceeds 170 ° C. The unit will need professional repairs.
ErrorCode_20 Boiler coffee overheating Brewing unit short circuit: occurs when the supply of the complete group has in short circuit. The unit will need professional repairs.
ErrorCode_21 Boiler steam overheating Zero crossing error: occurs when the C.A. It does not detect the signal zero crossing. The unit will need professional repairs.